About OLKLIN-DA (PH Controller For Cooling Towers)
Rather than removing calcium and magnesium ions, de-alkalization removes carbonate ions, exchanging them for chloride/sulphate ions
It reduces pH of water upto required level, to prevent biological fouling
Improper Water Treatment and/or lack of control will result in fouled chiller tubes and dirty towers costing high in excess energy and clean out expenses.
A good, well controlled, water treatment program will prevent these problems from occurring
Reliable pH Control for Cooling TowersOLKLIN-DA offers precise and efficient monitoring essential for maintaining water quality in cooling tower systems. Automatic temperature compensation and digital LCD display help operators ensure consistent pH management. By safeguarding equipment against scaling and corrosion, it supports long-term system reliability and energy savings.
Built for Industrial ConditionsDesigned as an industrial-grade solution, OLKLIN-DA features IP65 ingress protection, making it weather-resistant and suitable for harsh environments. Panel or wall mounting allows for flexible installation. The sturdy design and automatic alarm system guarantee durability and prompt response to pH fluctuations.
User-Friendly Operation and MaintenanceSimple mounting options, easy-to-read digital display, and a glass combination electrode sensor make OLKLIN-DA straightforward to use and maintain. The system is supported by relay contacts for automated dosing control and outputs compatible with standard industrial monitoring equipment.
FAQs of OLKLIN-DA (PH Controller For Cooling Towers):
Q: How do I install the OLKLIN-DA pH controller in my cooling tower system?
A: OLKLIN-DA can be mounted either on a panel or directly on a wall, thanks to its versatile design. Ensure the device is securely fixed near the sampling point and connected to the water stream. Follow the installation manual for proper wiring to a 230V AC power supply, sensor placement, and output connections for dosing control.
Q: What is the recommended process for calibrating the OLKLIN-DA pH controller?
A: Calibration should be performed using standard pH buffer solutions to ensure accuracy. Adjust the device through the user interface until readings match the reference buffers. For optimal performance, calibrate the controller periodically or after replacing the glass combination electrode sensor.
Q: Where should the OLKLIN-DA unit be stored before installation?
A: Store the controller and its components in a cool, dry, and ventilated area, away from direct sunlight. Maintain storage conditions as specified to ensure the sensor and electronics remain in optimal condition before installation.
Q: What benefit does automatic temperature compensation provide in OLKLIN-DA?
A: Automatic temperature compensation (ATC) ensures that pH readings remain accurate even as water temperature fluctuates within 0C to 50C. This feature reduces manual adjustments and supports reliable dosing control in varying operating conditions.
Q: When should the high/low pH alarm be adjusted on the controller?
A: Adjust the high/low pH alarm settings based on your systems water quality requirements. It is advisable to set or modify alarm thresholds during initial setup or whenever process conditions change, to promptly alert operators if pH levels deviate from safe operating limits.
Q: What type of sensor is used in OLKLIN-DA and how should it be maintained?
A: The controller employs a glass combination electrode sensor for precise pH measurement. Routine cleaning and periodic calibration are recommended to extend sensor life and maintain accuracy. Replace the sensor as needed according to manufacturer guidance.
Q: How does OLKLIN-DA benefit cooling tower water management?
A: OLKLIN-DA ensures real-time, reliable pH monitoring and automated control, supporting efficient use of chemicals for dosing and preventing issues such as scaling or corrosion. By maintaining optimal pH balance, the controller promotes equipment longevity and energy efficiency in cooling tower systems.